1.
J Invasive Cardiol ; 36(3)2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38441987

RESUMO

OBJECTIVES: Despite the introduction of improved drug eluting stents (DES), the rate of repeat revascularization procedures following percutaneous coronary interventions (PCI) in coronary chronic total occlusions (CTO) remains high. By leaving vessels uncaged and limiting length of stented segments, drug-coated balloons (DCB) represent an appealing alternative to DES for CTO-PCI. Since data supporting the use of DCBs in CTO-PCI is scarce, we compared the outcomes of patients undergoing CTO-PCI involving DCBs vs DES only. METHODS: From 2 prospective registries, outcomes of patients undergoing CTO-PCI involving DCBs and those undergoing PCI with DES only were compared. Outcomes included major adverse cardiac and cerebrovascular events (MACCE) and cardiovascular death (CV-death). RESULTS: Overall, 157 patients were studied; 112 (71%) underwent CTO-PCI involving DCBs and 45 (29%) were treated with DES only. Mean J-CTO score was 1.84 ± 0.7. Most CTO-lesions involved the right coronary artery, 88 (56%), and 26 (17%) cases were in-stent occlusions. In the DCB group, 46 (41%) lesions were treated with DCBs alone. Mean lengths of the stented segments in the DCB vs DES cohorts were 59 ± 28 mm vs 87 ± 37 mm (P less than .001), respectively. After 12 months, the MACCE rate was higher in the DES only vs DCB group (26% vs 11%, P=.03). Length of the stented segment was an independent predictor for MACCE (HR 1.15 [95% CI, 1.05-1.26] per 10-mm stent length). CONCLUSIONS: Revascularization of CTO lesions involving DCBs appears safe and potentially lowers MACCE rates compared to treatment with DES alone. Importantly, using DCBs for CTO treatment may reduce total stent length, which determines PCI outcomes.


Assuntos
Clorobenzenos , Oclusão Coronária , Intervenção Coronária Percutânea , Humanos , Oclusão Coronária/diagnóstico , Oclusão Coronária/cirurgia , Intervenção Coronária Percutânea/efeitos adversos , Estudos Prospectivos , Coração , Vasos Coronários/diagnóstico por imagem , Vasos Coronários/cirurgia
2.
Artigo em Inglês | MEDLINE | ID: mdl-38467531

RESUMO

BACKGROUND: Transcatheter aortic valve replacement (TAVR) is increasingly performed for the treatment of aortic stenosis. Computed tomography (CT) analysis is essential for pre-procedural planning. Currently available software packages for TAVR planning require substantial human interaction. We describe development and validation of an artificial intelligence (AI) powered software to automatically rend anatomical measurements and other information required for TAVR planning and implantation. METHODS: Automated measurements from 100 CTs were compared to measurements from three expert clinicians and TAVR operators using commercially available software packages. Correlation coefficients and mean differences were calculated to assess precision and accuracy. RESULTS: AI-generated annular measurements had excellent agreements with manual measurements by expert operators yielding correlation coefficients of 0.97 for both perimeter and area. There was no relevant bias with a mean difference of -0.07 mm and - 1.4 mm2 for perimeter and area, respectively. For the ascending aorta measured 5 cm above the annular plane, correlation coefficient was 0.95 and mean difference was 1.4 mm. Instruction for use-based sizing yielded agreement with the effective implant size in 87-88 % of patients for self-expanding valves (perimeter-based sizing) and in 88 % for balloon-expandable valves (area-based sizing). CONCLUSIONS: A fully automated software enables accurate and precise anatomical segmentation and measurements required for TAVR planning without human interaction and with high reliability.

3.
J Invasive Cardiol ; 36(4)2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38412438

RESUMO

OBJECTIVES: Percutaneous closure of a patent foramen ovale (PFO) for the prevention of recurrent paradoxical thromboembolic events has been shown to be safe and effective in randomized controlled trials. However, it remains uncertain if differences in the structure and design of the occluder devices impact the outcomes. The aim of this study was to compare results of percutaneous PFO closure using 2 widely used double-disc occluders. METHODS: Consecutive patients who underwent percutaneous PFO closure with the Abbott Amplatzer occluder (APO) or the Occlutech Figulla-Flex-II occluder (OPO) at the Heart Center Lucerne between February 2017 and December 2022 were included in a registry. The primary endpoint was effective closure of the PFO, defined as a residual shunt grade 0 or 1, assessed by contrast echocardiogram at 6-month follow-up. Secondary endpoints included procedural efficacy/safety and major adverse cardiovascular events during the hospital stay and at 6-month follow-up. RESULTS: One hundred ninety-three consecutive patients (mean age 51.7 ± 12.5 years; 39% women; Risk of Paradoxical Embolism (RoPE) score = 7, IQR = 6-8) underwent percutaneous PFO closure with the APO (120 patients, 62.2%) or the OPO (73 patients, 37.8%). Main indications for closure were crypotogenic stroke in 168 patients (87.1%) and peripheral embolism in 13 patients (6.7%). At baseline, right-to-left shunt (RLS) greater than or equal to grade 2 was present in 189 patients (97.9%). Immediate procedural success was 99.5%. In 1 patient, an air embolism occurred during positioning of the APO occluder with transient chest pain and electrocardiogram changes, but without further sequelae to the patient. At 6-month follow-up, effective closure was achieved in 185 patients (95.8%; APO: 96.6% vs OPO: 94.5%, P = .30). Rates of atrial fibrillation and recurrent thromboembolic events were 4.2 and 0.5%, respectively. CONCLUSIONS: PFO closure is safe and effective when performed with either the self-expanding Abbott Amplatzer or Occlutech Figulla Flex II PFO occluder.


Assuntos
Forame Oval Patente , Dispositivo para Oclusão Septal , Acidente Vascular Cerebral , Tromboembolia , Humanos , Feminino , Adulto , Pessoa de Meia-Idade , Masculino , Forame Oval Patente/diagnóstico , Forame Oval Patente/cirurgia , Forame Oval Patente/complicações , Resultado do Tratamento , Ecocardiografia , Acidente Vascular Cerebral/epidemiologia , Acidente Vascular Cerebral/etiologia , Acidente Vascular Cerebral/prevenção & controle , Dispositivo para Oclusão Septal/efeitos adversos , Tromboembolia/etiologia , Cateterismo Cardíaco/métodos
4.
J Am Heart Assoc ; 13(5): e032250, 2024 Mar 05.
Artigo em Inglês | MEDLINE | ID: mdl-38390801

RESUMO

BACKGROUND: Chronic inflammatory disease (CID) accelerates atherosclerosis and the development of aortic stenosis. Data on long-term outcomes after transcatheter aortic valve implantation (TAVI) in those patients are missing. The aim of this study was to investigate the clinical long-term outcomes of patients with and without autoimmune-related CID undergoing TAVI for the treatment of severe aortic stenosis. METHODS AND RESULTS: From a prospective registry, consecutive patients with TAVI were included. Baseline clinic and imaging data (echocardiographic and computed tomography) were analyzed. Long-term (up to 5 years) clinical and echocardiographic outcomes were studied. Of 1000 consecutive patients (mean age 81±6 years, 46% female), 107 (11%) had CID; the most frequent entities included polymyalgia rheumatica (31%) and rheumatoid arthritis (28%). Patients with CID were predominantly female (60% versus 44%, P=0.002) and more often had pulmonary disorders (21% versus 13%, P=0.046) and atrial fibrillation (32% versus 20%, P=0.003). The presence of CID was associated with a higher rate of postinterventional infection (5% versus 1%, P=0.007) and further emerged as a risk factor for rehospitalization for bleeding or infection (hazard ratio, 1.93 and 1.62, respectively). Premature valve degeneration, endocarditis, and all-cause mortality were not increased among patients with CID. CONCLUSIONS: This real-world analysis found that patients with CID undergoing TAVI were associated with a higher risk of postinterventional infectious complications and rehospitalization due to infection. However, valve durability and survival seem not to differ between patients with TAVI with versus without CID.


Assuntos
Estenose da Valva Aórtica , Fibrilação Atrial , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Humanos , Feminino , Idoso , Idoso de 80 Anos ou mais , Masculino , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Resultado do Tratamento , Estenose da Valva Aórtica/complicações , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Fatores de Risco , Fibrilação Atrial/complicações , Doença Crônica , Sistema de Registros
5.
Struct Heart ; 7(6): 100214, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-38046862

RESUMO

Background: Motion artifacts in planning computed tomography (CT) for transcatheter aortic valve implantation (TAVI) can potentially skew measurements required for procedural planning. Whether such artifacts may affect safety or efficacy has not been studied. Methods: We conducted a retrospective analysis of 852 consecutive patients (mean age, 82 years; 47% women) undergoing TAVI-planning CT at a tertiary care center. Two independent observers divided CTs according to the presence of motion artifacts at the annulus level (Motion vs. Normal group). Endpoints included surrogate markers for inappropriate valve selection: annular rupture, valve embolization or misplacement, need for a new permanent pacemaker, paravalvular leak (PVL), postprocedural transvalvular gradient, all-cause death. Results: Forty-six (5.4%) patients presented motion artifacts on TAVI-planning CT (Motion group). These patients had more preexisting heart failure, moderate-severe mitral regurgitation, and atrial fibrillation. Interobserver variability of annular measurement (Normal vs. Motion group) did not differ for mean annular diameter but was significantly different for perimeter and area. Presence of motion artifacts on planning CT did not affect the prevalence of PVL (≥moderate PVL 0% vs. 2.5% p = 0.5), mean transvalvular gradient (6±3 mmHg vs 7±5 mmHg, p = 0.1), or the need for additional valve implantation (0% vs. 2.8%, p = 0.6). One annular rupture occurred (Normal group). Pacemaker implantation, procedural duration, hospital stay, 30-day outcomes, and all-cause mortality did not differ between the groups. Conclusions: Motion artifacts on planning CT were found in about 5% of patients. Measurements for valve selection were possible without the need for repeat CT, with mean diameter-derived annulus measurement being the most accurate. Motion artifacts were not associated with worse outcomes.

6.
J Invasive Cardiol ; 35(12)2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-38108869

RESUMO

OBJECTIVES: The Allegra-THV is a novel, self-expanding THV with supra-annular bovine leaflets. The valve is available in 3 different sizes and is delivered through an 18 French sheath. To determine the safety and efficacy of the Allegra transcatheter heart valve (THV; Biosensors) for the treatment of severe aortic valve stenosis under real-world conditions. METHODS: Consecutive patients undergoing transcatheter aortic valve replacement (TAVR) at the Heart-Centre Lucerne with the Allegra-THV were included. Echocardiographic data were collected at baseline, before discharge, and at 1-year follow-up; clinical outcomes were recorded for up to 3 years. Clinical endpoints were defined according to the definitions of the Valve-Academic-Research-Consortium. RESULTS: One hundred-three patients (age 81 ± 7 years, 63% women) were enrolled. Median European System for Cardiac Operative Risk Evaluation II score was 4.1% (IQR 1.8%-4.2%). Mean aortic valve gradient was 6.9 ± 3.3 mm Hg and 7.7 ± 3.3 mm Hg, and an effective orifice area was 2.1 ± 0.5 cm2 and 2.0 ± 0.5 cm2 at 30 days and 1-year follow-up, respectively. More than mild paravalvular leak was observed in 2.0% of patients at 30 days and 3.3% at 1 year. At 1-year follow-up, 14.7% of patients required implantation of a new permanent pacemaker, 1 patient had endocarditis with an uneventful clinical course and good THV-function after antibiotic therapy, and no thrombosis, structural-valve-detoriation (SVD), or non-SVD had occurred. At 3-year follow-up, rates of all-cause and cardiovascular mortality were 31.4% and 18.8%, respectively. CONCLUSIONS: Transfemoral implantation of the Allegra-THV resulted in favorable clinical and echocardiographic outcomes at up to 3-year follow-up. Head-to-head randomized clinical trials are necessary to determine if the Allegra-THV valve performs as well as current generation valves.


Assuntos
Ecocardiografia , Valvas Cardíacas , Humanos , Animais , Bovinos , Feminino , Idoso , Idoso de 80 Anos ou mais , Masculino , Terfenadina , Cateteres
9.
Am J Cardiol ; 200: 146-152, 2023 08 01.
Artigo em Inglês | MEDLINE | ID: mdl-37321028

RESUMO

Subclinical leaflet thrombosis, identified as hypoattenuated leaflet thickening (HALT) on cardiac computed tomography scan, has been observed after transcatheter aortic valve replacement (TAVR). However, data on HALT after the implant of the supra-annular ACURATE neo/neo2 prosthesis are limited. This study aimed to determine the prevalence and risk factors for the development of HALT after TAVR with the ACURATE neo/neo2. A total of 50 patients who received the ACURATE neo/neo2 prosthesis were prospectively enrolled. Patients underwent a contrast-enhanced multidetector row cardiac computed tomography scan at before, after, and 6 months after TAVR. At the 6-month follow-up, HALT was detected in 16% (8 of 50 patients). These patients had a lower implant depth of the transcatheter heart valve (8 ± 2 mm vs 5 ± 2 mm, p = 0.001), less calcified native valve leaflets, a better expansion of the frame at the level of the left ventricular outflow tract, and were less often hypertensive. Thrombosis of the sinus of Valsalva occurred in 18% (9/50). There was no difference in the anticoagulation regimen between patients with and without thrombotic findings. In conclusion, HALT was present in 16% of patients at 6 months follow-up, patients presenting with HALT had a lower implant depth of the transcatheter heart valve, and HALT was detected in patients on oral anticoagulation therapy.


Assuntos
Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Trombose , Substituição da Valva Aórtica Transcateter , Humanos , Próteses Valvulares Cardíacas/efeitos adversos , Resultado do Tratamento , Valva Aórtica/cirurgia , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/métodos , Desenho de Prótese , Trombose/diagnóstico por imagem , Trombose/epidemiologia , Trombose/etiologia , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/etiologia
10.
BMC Cardiovasc Disord ; 23(1): 306, 2023 06 17.
Artigo em Inglês | MEDLINE | ID: mdl-37330463

RESUMO

BACKGROUND: The Sentinel cerebral embolic protection device (CEP) aims to reduce the risk of stroke during transcatheter aortic valve replacement (TAVR). We performed a systematic review and meta-analysis of propensity score matched (PSM) and randomized controlled trials (RCT) investigating the effect of the Sentinel CEP to prevent strokes during TAVR. METHODS: Eligible trials were searched through PubMed, ISI Web of science databases, Cochrane database, and proceedings of major congresses. Primary outcome was stroke. Secondary outcomes included all-cause mortality, major or life-threatening bleeding, major vascular complications and acute kidney injury at discharge. Fixed and random effect models were used to calculate the pooled risk ratio (RR) with 95% confidence intervals (CI) and absolute risk difference (ARD). RESULTS: A total of 4066 patients from 4 RCTs (3'506 patients) and 1 PSM study (560 patients) were included. Use of Sentinel CEP was successful in 92% of patients and was associated with a significantly lower risk of stroke (RR: 0.67, 95% CI: 0.48-0.95, p = 0.02. ARD: -1.3%, 95% CI: -2.3 - -0.2, p = 0.02, number needed to treat (NNT) = 77), and a reduced risk of disabling stroke (RR: 0.33, 95% CI: 0.17-0.65. ARD: -0.9%, 95% CI: -1.5 - -0.3, p = 0.004, NNT = 111). Use of Sentinel CEP was associated with a lower risk of major or life-threatening bleeding (RR: 0.37, 95% CI: 0.16-0.87, p = 0.02). Risk for nondisabling stroke (RR: 0.93, 95% CI: 0.62-1.40, p = 0.73), all-cause mortality (RR: 0.70, 95% CI: 0.35-1.40, p = 0.31), major vascular complications (RR: 0.74, 95% CI: 0.33-1.67, p = 0.47) and acute kidney injury (RR: 0.74, 95% CI: 0.37-1.50, p = 0.40) were similar. CONCLUSIONS: The use of CEP during TAVR was associated with lower risks of any stroke and disabling stroke with an NNT of 77 and 111, respectively.


Assuntos
Estenose da Valva Aórtica , Dispositivos de Proteção Embólica , Embolia Intracraniana , Acidente Vascular Cerebral , Substituição da Valva Aórtica Transcateter , Humanos , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/complicações , Pontuação de Propensão , Fatores de Risco , Resultado do Tratamento , Ensaios Clínicos Controlados Aleatórios como Assunto , Acidente Vascular Cerebral/etiologia , Acidente Vascular Cerebral/prevenção & controle , Embolia Intracraniana/diagnóstico por imagem , Embolia Intracraniana/etiologia , Embolia Intracraniana/prevenção & controle
12.
Catheter Cardiovasc Interv ; 102(2): 339-347, 2023 08.
Artigo em Inglês | MEDLINE | ID: mdl-37232417

RESUMO

BACKGROUND: Growing interest in neuroprotection in transcatheter aortic valve replacement (TAVR) has catalyzed the development of cerebral protection systems (CPS). OBJECTIVES: Report insights from consecutive real-world patients undergoing TAVR with the Sentinel-CPS. METHODS: Patients with severe aortic stenosis undergoing TAVR from April 2019 to May 2022 were enrolled in a prospective registry. The reason for unsuccessful Sentinel-CPS deployment and the amount of debris captured by the filters were prospectively recorded. RESULTS: The Sentinal CPS was successfully deployed in 330 patients (85%, Group 1). Deployment was not attempted, unsuccessful or only partially successful in 59 patients (15%, Group 2), caused by anatomical factors such as tortuosity, heavy calcification or small dimensions of radial or brachial artery in 46, technical aspects such as puncture failure or dissection in 5 or use of right radial access for the pigtail in 6. Debris was captured in 98% of patients in Group 1. In 40%, the amount of debris was graded moderate or extensive. Predictors for moderate/extensive debris were moderate/severe aortic calcification (OR 1.50, CI 1.05-2.15, p = 0.03), pre- and postdilatation (OR 1.97, CI 1.02-3.79, p = 0.04 and OR 1.71, CI 1.01-2.89, p = 0.048). The risk of stroke was numerically lower in patients who underwent TAVR with the Sentinel CPS (2.1 vs. 5.1%, respectively, p = 0.15). There was no stroke during CPS deployment, but one patient had a stroke immediately after device retrieval. CONCLUSIONS: The Sentinel-CPS was successfully deployed in 85% of patients. Predictors for moderate/extensive debris captured were moderate/severe aortic calcification, pre- and postdilatation.


Assuntos
Estenose da Valva Aórtica , Dispositivos de Proteção Embólica , Acidente Vascular Cerebral , Substituição da Valva Aórtica Transcateter , Humanos , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/etiologia , Resultado do Tratamento , Acidente Vascular Cerebral/etiologia , Fatores de Risco
14.
CJC Open ; 5(1): 77-85, 2023 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-36700188

RESUMO

Background: Left ventricular (LV) unloading via the percutaneous micro-axial Impella pump is increasingly used in patients with anterior ST-segment elevation myocardial infarction (STEMI) and overt cardiogenic shock. In this context, the evolution of cardiac function and dimensions beyond hospital discharge remains uncertain. We aimed to characterize echocardiographic changes over time in patients with acute anterior STEMI treated with an Impella device. Methods: From an ongoing prospective registry, consecutive patients with acute anterior STEMI managed with an Impella device were extracted. Transthoracic echocardiography was performed at index hospitalization and at first outpatient follow-up. Predictors of response, defined as a ≥ 10% absolute increase in left ventricular ejection fraction (LVEF) at follow-up, were sought. Results: A total of 66 patients (89.4% male, aged 64.3 ± 11.6 years) with anterior STEMI were treated with an Impella device in the first 24 hours of hospitalization, from 2014 to 2022. In-hospital mortality was 24%. Major bleeding and vascular complications requiring surgery occurred in 24% and 11% of patients, respectively. At baseline, mean LVEF was 34% ±12%. At follow-up, survivors showed a significant increase in LVEF (P < 0.0001), whereas LV dimensions, diastolic parameters, and measures of right ventricular dimension and function remained stable. Overall, 28 patients had a ≥ 10% absolute increase in LVEF at follow-up. Baseline creatinine was the only significant predictor of response at univariate analysis. Conclusions: Among patients with anterior STEMI requiring mechanical hemodynamic support with an Impella device, the majority of survivors showed a sustained increase in LV function, without evidence of adverse remodelling. This signal warrants further investigation in dedicated trials.


Contexte: La décharge du ventricule gauche (VG) à l'aide de la pompe microaxiale percutanée Impella est de plus en plus employée chez les patients qui présentent un infarctus du myocarde avec élévation du segment ST (STEMI) et un choc cardiogénique manifeste. Dans ce contexte, l'évolution de la fonction et des dimensions cardiaques après le congé de l'hôpital demeure incertaine. Nous avons cherché à caractériser les variations des paramètres échocardiographiques au fil du temps chez les patients ayant subi un STEMI antérieur aigu traités au moyen d'un dispositif Impella. Méthodologie: À partir d'un registre prospectif actif, nous avons extrait les dossiers de patients consécutifs ayant subi un STEMI antérieur aigu et pris en charge au moyen d'un dispositif Impella. Une échocardiographie transthoracique a été effectuée durant l'hospitalisation de référence puis à la première visite de suivi ambulatoire. Les facteurs prédictifs de la réponse, définis comme une augmentation absolue ≥ 10 % de la fraction d'éjection ventriculaire gauche (FEVG) au moment du suivi, ont été recherchés. Résultats: Au total, 66 patients (89,4 % d'hommes, âgés de 64,3 ± 11,6 ans) ayant subi un STEMI antérieur ont été traités au moyen d'un dispositif Impella pendant les 24 premières heures de l'hospitalisation, entre 2014 et 2022. Le taux de mortalité hospitalière était de 24 %. Des hémorragies majeures et des complications vasculaires ayant nécessité une intervention chirurgicale sont survenues chez 24 % et 11 % des patients, respectivement. Au début de l'étude, la FEVG moyenne était de 34 % ± 12 %. Lors du suivi, les survivants affichaient une augmentation significative de la FEVG (p < 0,0001), alors que les dimensions du VG, les paramètres diastoliques et les mesures de la taille et de la fonction du ventricule droit étaient demeurés stables. Globalement, 28 patients affichaient une augmentation absolue de la FEVG ≥ 10 % lors du suivi. D'après l'analyse univariée, la créatininémie initiale était le seul facteur prédictif important de la réponse. Conclusions: Parmi les patients ayant subi un STEMI antérieur nécessitant un support mécanique hémodynamique au moyen d'un dispositif Impella, une augmentation durable de la fonction ventriculaire gauche, sans signe de remodelage indésirable, a été observée chez la majorité des survivants. Ce signal justifie une évaluation plus approfondie dans le cadre d'essais cliniques conçus à cet effet.

15.
Cardiovasc Revasc Med ; 46: 29-35, 2023 01.
Artigo em Inglês | MEDLINE | ID: mdl-36085285

RESUMO

BACKGROUND: Treatment of in-stent restenosis (ISR) is challenging and treatment failure rate remains high. Correction of stent under-expansion and neointimal compression using the twin-layer OPN™ highly non-compliant balloon (NCB) at high pressure (>30 atm) may lead to increased luminal gain and thus better clinical outcomes. We evaluated periprocedural safety and clinical long-term outcomes after ISR treatment using the OPN™ NCB in a real-world population. METHODS: From an ongoing registry, consecutive ISR patients treated with the OPN™ NCB at a tertiary cardiology center in Switzerland were analyzed. We evaluated procedural efficacy, periprocedural complications, target lesion/vessel failure (TLF/TVF), and major adverse cardiovascular events (MACE). RESULTS: Totally, 208 ISR lesions were treated in 188 patients (mean age 68 ± 13 years, 78 % males). Most lesions were moderately to heavily calcified (89 %), the majority (70.2 %) had complex lesion characteristics (AHA Type B2/C lesions) and 50.5 % were non-focal ISR lesions. After ISR treatment using high pressure pre- and post-dilatation (mean pressure 33 ± 6 atm) with the OPN™ NCB device, the rate of major complications was low (0.96 % coronary perforation, 4 % major dissections, 1.9 % no-reflow and 0.5 % acute vessel closure). At 1-year follow-up, MACE occurred in 19.7 %; 15.4 % patients had TVF; MI and stent thrombosis was found in 5.9 % and 2.1 % of all patients, respectively; and 5 patients died. CONCLUSIONS: For ISR treatment, using the super non-compliant OPN™ balloon at very high pressures is safe. Moreover, its use might lead to a low rate of TLF/TVF during long-term follow-up, but this requires further evaluation in dedicated comparative trials.


Assuntos
Angioplastia Coronária com Balão , Reestenose Coronária , Intervenção Coronária Percutânea , Masculino , Humanos , Pessoa de Meia-Idade , Idoso , Idoso de 80 Anos ou mais , Feminino , Angioplastia Coronária com Balão/efeitos adversos , Reestenose Coronária/diagnóstico por imagem , Reestenose Coronária/etiologia , Reestenose Coronária/terapia , Intervenção Coronária Percutânea/efeitos adversos , Stents/efeitos adversos , Suíça , Resultado do Tratamento , Angiografia Coronária/efeitos adversos
16.
Cardiol J ; 30(2): 196-203, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-34490602

RESUMO

BACKGROUND: Covered coronary stent (CS) implantation is associated with a high risk for in-stent restenosis (ISR) and stent thrombosis (ST). We describe the outcomes after overstenting ("burying") CS using contemporary drug-eluting stents (DES). METHODS: We analyzed short- and long-term outcomes of consecutive patients who had had a CS implanted, which was consecutively covered ("buried") with a third-generation DES. CSs were primarily post-dilated and then covered with a longer DES overlapping the proximal and distal edges of the CS. To ensure optimal stent expansion and appositions, all lesions were post-dilated using adequately sized non-compliant balloons. RESULTS: Between 2015 and 2020, 23 patients (mean age 67 ± 14 years, 74% males) were treated using this novel approach. Reasons for implanting CS included treatment of coronary aneurysms (n = 7; 30%), coronary perforations (n = 13; 57%), and aorto-ostial dissections (n = 3; 13%). All CSs were successfully deployed, and no peri-procedural complications occurred. The median time of follow-up was 24.5 (interquartile range [IQR] 11.7-37.9) months. All patients had a 1-month follow-up (FU) and 19/23 (83%) patients had 12-month FU (FU range 1-60 months). No probable or definite STs occurred, and no cardiovascular deaths were observed. Among patients undergoing angiographic FU (11/23 [48%]), 1/23 showed angiographically significant ISR 6 months post CS implantation. CONCLUSIONS: Burying a coronary CS under a DES appears to be a safe and promising strategy to overcome the limitations of the currently available CS devices, including a relatively high risk for target lesion failure due to ISR and ST.


Assuntos
Angioplastia Coronária com Balão , Reestenose Coronária , Stents Farmacológicos , Intervenção Coronária Percutânea , Trombose , Masculino , Humanos , Pessoa de Meia-Idade , Idoso , Idoso de 80 Anos ou mais , Feminino , Stents Farmacológicos/efeitos adversos , Angioplastia Coronária com Balão/efeitos adversos , Angiografia Coronária/efeitos adversos , Resultado do Tratamento , Fatores de Risco , Reestenose Coronária/diagnóstico , Reestenose Coronária/etiologia , Reestenose Coronária/terapia , Stents/efeitos adversos , Trombose/etiologia , Intervenção Coronária Percutânea/efeitos adversos
17.
Am J Cardiol ; 186: 216-222, 2023 01 01.
Artigo em Inglês | MEDLINE | ID: mdl-36333149

RESUMO

The increasing prevalence of aortic stenosis (AS) and the increasing number of patients indicated for transcatheter aortic valve implantation (TAVI) can lead to increased hospital constraints. This study aimed to compare, from the hospital perspective, the costs, resource use, and 30-day clinical outcomes of patients who underwent TAVI under an optimized or standard clinical pathway. A single-center, retrospective study was conducted among patients with native AS who underwent TAVI between January 2018 and March 2021. Patients who underwent optimized lean TAVI were propensity-score matched 1:1 to those who underwent standard TAVI. In-hospital costs and 30-day clinical outcomes were compared between the 2 groups. A total of 182 patients (91 in each group) were included in the final analysis. Baseline covariates were well balanced after matching. Patients who underwent lean TAVI had shorter length of stay (median [interquartile range] 3.0 days [2.0 to 6.0] vs 6.0 days [5.0 to 9.0], p <0.001). Patients in the lean TAVI group incurred lower total costs than did those in the standard TAVI group (mean ± SD: $41,346 ± 10,062 vs $50,471 ± 15,115, p = 0.002). There was no between-group difference in 30-day all-cause mortality (2.2% vs 1.1%, p = 0.573) and pacemaker implantations (5.5% vs 6.6%, p = 0.788). Rates of procedural complications were comparable between groups. In conclusion, lean TAVI leads to hospital efficiencies without compromising patient safety. Efforts to streamline the TAVI procedure should be encouraged to improve access to TAVI for patients with AS, amid resource constraints.


Assuntos
Estenose da Valva Aórtica , Implante de Prótese de Valva Cardíaca , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/métodos , Estudos Retrospectivos , Resultado do Tratamento , Pontuação de Propensão , Valva Aórtica/cirurgia , Implante de Prótese de Valva Cardíaca/métodos , Fatores de Risco
18.
J Invasive Cardiol ; 34(12): E850-E857, 2022 12.
Artigo em Inglês | MEDLINE | ID: mdl-36328515

RESUMO

OBJECTIVES: Patients with severe mitral regurgitation (MR) frequently present with concomitant right ventricular (RV) dysfunction and tricuspid regurgitation (TR). We aimed to investigate the prognostic relevance of RV function, RV dimension, and TR in patients undergoing percutaneous intervention for MR. METHODS: Consecutive patients undergoing percutaneous mitral valve intervention were enrolled in the prospective MitraSwiss registry. Tricuspid annular plane systolic excursion (TAPSE), pulmonary artery systolic pressure (PASP), right ventricular pulmonary arterial coupling (RVC, defined as TAPSE/ PASP ratio), indexed tricuspid annulus (TA) dimension, and TR severity grade were analyzed at baseline, post procedure, and at 6-month follow-up. The endpoints of all-cause mortality, hospitalization for heart failure, and the combined endpoint of the 2 were observed during long-term follow-up (up to 4 years). RESULTS: We analyzed 218 patients (mean age, 76 ± 9 years; 36% female). Edge-to-edge mitral valve repair resulted in an increase in TAPSE and RVC ratio and a decrease in indexed TA and PASP, but concomitant TR did not change significantly. In multivariable analysis, RV dysfunction and moderate/severe TR were independently associated with increased all-cause mortality (hazard ratio, 1.61; 95% confidence interval, 1.05-2.46; P=.03 and hazard ratio, 2.10; 95% confidence interval, 1.34-3.29; P<.01, respectively) and moderate/severe TR was further an independent predictor for hospitalization for heart failure and for the combined endpoint. CONCLUSION: Treatment of MR resulted in favorable changes of RV function and dimension but did not reduce TR in the majority of patients. TR at baseline remained the strongest predictor for outcomes, outperforming parameters of RV function and dimension.


Assuntos
Insuficiência Cardíaca , Função Ventricular Direita , Humanos , Feminino , Idoso , Idoso de 80 Anos ou mais , Masculino , Estudos Prospectivos , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/cirurgia
19.
Cardiol J ; 29(6): 906-916, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36385601

RESUMO

BACKGROUND: Limus-eluting stents have become the mainstay for percutaneous coronary intervention (PCI). However, even with the latest generation drug-eluting stent, in-stent restenosis and very late stent thrombosis remain a concern. The Selution SLR™ drug-coated balloon (DCB) is a novel sirolimus-coated balloon that provides a controlled release of the antiproliferative drug. Herein we evaluated its performance in a real-world patient cohort with complex coronary artery lesions. METHODS: Patients undergoing PCI using the Selution SLR™ DCB were analyzed from the prospective SIROOP registry. We evaluated procedural success and clinical outcomes, including major adverse cardiovascular event (MACE), cardiac death, target vessel myocardial infarction and target lesion revascularization. RESULTS: From September 2020 to April 2021, we enrolled 78 patients (87 lesions) treated using a "DCB only" strategy. The mean age was 66.7 ± 10.4 years and 28 (36%) presented with an acute coronary syndrome. Almost all lesions were type B2/C 86 (99%) and 49 (63%) had moderate to severe calcifications. Procedural success was 100%. After a median follow-up of 11.2 months (interquartile range: 10.0-12.6), MACE occurred in 5 (6.8%) patients. No acute vessel closure was observed. CONCLUSIONS: In complex coronary lesions, a "DCB only" strategy using the Selution SLR™ DCB is not just safe and feasible, but also seems to be associated with a low rate of MACE at 1-year follow-up. Our promising results warrant further evaluation in a dedicated comparative trial.


Assuntos
Doença da Artéria Coronariana , Reestenose Coronária , Stents Farmacológicos , Intervenção Coronária Percutânea , Humanos , Pessoa de Meia-Idade , Idoso , Intervenção Coronária Percutânea/efeitos adversos , Sirolimo/efeitos adversos , Estudos Prospectivos , Resultado do Tratamento , Metais , Reestenose Coronária/diagnóstico por imagem , Reestenose Coronária/etiologia , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/cirurgia , Angiografia Coronária
20.
J Invasive Cardiol ; 34(10): E739-E742, 2022 10.
Artigo em Inglês | MEDLINE | ID: mdl-36121924

RESUMO

OBJECTIVES: During the past few years, physicians have optimized transcatheter aortic valve replacement and its periprocedural management, with the minimalist approach becoming popular. We aimed to further simplify the procedure using a single femoral access (the "all-in-one" technique). Here, we report a multicenter experience with TAVR with Acurate neo/neo2 transcatheter heart valves (Boston Scientific) through a single, large-bore, femoral sheath. METHODS: Patients underwent TAVR with the Acurate neo or neo2 through a single femoral access at 4 centers. The large sheath was used for both the delivery catheter and the pigtail used to visualize the aortic root. RESULTS: A total of 157 patients (59% women) with a mean age of 82 ± 6 years underwent TAVR with the Acurate neo (n = 100) or the Acurate neo2 (n = 57). The procedure was successfully performed through a single large sheath in all patients. Median duration of hospitalization stay was 2 days (interquartile range, 1-3 days). On echocardiography before discharge, the mean gradient was 7 ± 3 mm Hg and 7 patients (4.4%) had more than mild paravalvular leak. At 30 days, a major vascular complication had occurred in 2 patients (1.3%), 2 patients (1.3%) had suffered a stroke, and only 4 patients (2.5%) had required new permanent pacemaker implantation. A total of 3 patients (1.9%) had died. CONCLUSIONS: An all-in-one access technique allows safe implantation of Acurate neo and neo2 transcatheter heart valves, with low rates of periprocedural complications and favorable short-term outcomes.


Assuntos
Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Idoso , Idoso de 80 Anos ou mais , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico , Estenose da Valva Aórtica/etiologia , Estenose da Valva Aórtica/cirurgia , Feminino , Humanos , Masculino , Desenho de Prótese , Fatores de Tempo , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/métodos , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...